Ocr template, Ocr template -16, Ocr template parameter # f1 23h – Rice Lake Motorola DS457 Laser Scanner User Manual
Page 208
11 - 16 DS457 Fixed Mount Imager Integration Guide
OCR Template
Parameter # F1 23h
This option creates a template for precisely matching scanned OCR characters to a desired input format.
Carefully constructing an OCR template eliminates scanning errors.
To set or modify the OCR decode template, scan the
bar code, then bar codes corresponding
to numbers and letters on the following pages to form the template expression. Then scan
.
The default is
54R
which accepts any character OCR strings.
Required Digit (9)
Only a numeric character is allowed in this position.
Template
Valid data
Valid data
Invalid data
99999
12987
30517
123AB
Required Alpha (A)
Only an alpha character is allowed in this position.
Template
Valid data
Valid data
Invalid data
AAA
ABC
WXY
12F
OCR Template
End of Message
9