Rice Lake Motorola DS457 Laser Scanner User Manual
Page 374
A - 2
DS457 Fixed Mount Imager Integration Guide
Timeout Between Decodes, Same Symbol
89h
0.6 Sec
Continuous Bar Code Read
F1 89h
Disable
Mirrored Image
F1h 70h
Disable
Mobile Phone/Display Mode
F1h CCh
Disable
Validate Concatenated Parameter Bar Codes
F1h B4h
Disable
PDF Prioritization
F1h CFh
Disable
PDF Prioritization Timeout
F1h D0h
200 ms
Multicode Mode
F1h A5h
Disable
Multicode Expression
F1h 95h
1
Imager Preferences
Decoding Autoexposure
F0h 29h
Enable
Decoding Illumination
F0h 2Ah
Enable
Decode Aiming Pattern
F0h 32h
Enable
Aim Brightness
F0h 9Ch
0
Illumination Brightness
F0h 9Dh
10
Low Light Enhancement
F1h 64h
Disable
Presentation Mode Field of View
F1h 61h
Default (Reduced)
Frame Rate
F1h A2h
Auto
Image Capture Autoexposure
F0h 68h
Enable
Image Capture Illumination
F0h 69h
Enable
Fixed Gain
F1h 38h
50
Exposure Time
F4h F1h 37h
100 (10 ms)
Snapshot Mode Timeout
F0h 43h
0 (30 seconds)
Snapshot Aiming Pattern
F0h 2Ch
Enable
Presentation Snapshot by Motion
F1h 87h
Disable
Continuous Snapshot
F1h 88h
Disable
Image Cropping
F0h 2Dh
Disable
Crop to Pixel Addresses
F4h F0h 3Bh;
F4h F0h 3Ch;
F4h F0h 3Dh;
F4h F0h 3Eh
0 top, 0 left, 479 bottom,
751 right
Table A-1
Standard Default Parameters Table (Continued)
Parameter
Parameter
Number
Default
Page
Number
1
User selection is required to configure this interface and this is the most common selection.