Simple serial interface default parameters, Simple serial interface default parameters -8 – Rice Lake Motorola DS457 Laser Scanner User Manual

Page 134

Advertising
background image

8 - 8

DS457 Fixed Mount Imager Integration Guide

Simple Serial Interface Default Parameters

This section describes how to set up the imager with an SSI host. When using SSI, program the imager via bar

code menu or SSI hosts commands.

Throughout the programming bar code menus, asterisks (

*

) indicate default values.

Table 8-3

lists the defaults for the SSI host. There are two ways to change the default values:

Scan the appropriate bar codes in this guide. These new values replace the standard default values in

memory. To recall the default parameter values, scan the

*Restore Defaults

bar code on

page 6-5

.

Download data through the device’s serial port using SSI. Hexadecimal parameter numbers appear in

this chapter below the parameter title, and options appear in parenthesis beneath the accompanying bar

codes. Refer to the

Simple Serial Interface (SSI) Programmer’s Guide

for detailed instructions for

changing parameters using this method.

*

Baud Rate 9600

(06h)

Feature/Option

*

Indicates Default

Option Hex Value for programming

via SSI command

NOTE

Most computer monitors allow scanning the bar codes directly on the screen. When scanning from the

screen, be sure to set the document magnification to a level where you can see the bar code clearly, and

bars and/or spaces are not merging.

NOTE

See

Appendix A, Standard Default Parameters

for all user preferences, hosts, symbologies, and

miscellaneous default parameters.

Table 8-3

SSI Default Table

Parameter

Parameter

Number

Default

Page

Number

Select SSI Host

N/A

N/A

8-9

Baud Rate

9Ch

9600

8-10

Parity

9Eh

None

8-11

Check Parity

97h

Disable

8-12

Software Handshaking

9Fh

ACK/NAK

8-12

Host RTS Line State

9Ah

Low

8-13

Decode Data Packet Format

EEh

Send Raw Decode Data

8-13

Host Serial Response Time-out

9Bh

2 sec

8-14

Host Character Time-out

EFh

200 msec

8-15