9145ELB NID Software User’s Manual

System Configuration

IP/SNMP Agent Configuration

28

The System Log contains the log of all enabled Trap events.

1. To configure Traps, select Trap Configuration (2) from the System Configuration menu.

The Trap Configuration screen (Figure 3-17) opens.

2. Select the number of the trap group to change and press Enter. Press the Space bar to

select Log Only, Send Only, Both Log And Send, or Disabled.

The Master Trap Control setting overrides all other trap settings. For example, if the
Master Trap Control is set to Log Only, rather than set to Both Log And Send (as shown),
all the other traps will only log alarm events, regardless of the individual trap settings. If
the Master Trap Control is set to Log And Send, the individual traps will perform
according to their individual settings. Setting the Master Trap Control setting to Disabled
will disable all traps.

Trap Config Item

Traps Affected

MIB Location

cpFanOK

cpFanStatus.my

cpFanSlow

cpFanStatus.my

cpFanFailed

cpFanStatus.my

cpTemperatureOverHighThresholdAlarm

cpStatus.my

cpTemperatureHighThresholdAlarmCleared

cpStatus.my

cpTemperatureWarningApproachingHighThreshold cpStatus.my

cpTemperatureHighThresholdWarningCleared

cpStatus.my

cpTemperatureAlarmUnderLowThreshold

cpStatus.my

cpTemperatureLowThresholdAlarmCleared

cpStatus.my

cpTemperatureWarningApproachingLowThreshold cpStatus.my

cpTemperatureLowThresholdWarningCleared

cpStatus.my

SFP Traps cpSfpRemoved

cpSfpStatus.my

cpSfpInsertedInvalid

cpSfpStatus.my

cpSfpInsertedValid

cpSfpStatus.my

cpSfpTxOk

cpSfpStatus.my

cpSfpTxWarning

cpSfpStatus.my

cpSfpTxFailure

cpSfpStatus.my