Diagnostics
9145ELB NID Software User’s Manual
Loopback Setup
47
Figure 4-3 Ethernet Loopback Setup screen
1. To select a port, type 1 and press Enter. Press the Space bar to select a setting and then
press Enter. Settings include loopback for each of the 16 User Ports and two 10G ports,
and Clear Loopback.
NOTE: When 10G2 UNI is enabled, User Ports 9-16 are disabled and you will not be able to set
a loopback state on those ports.
2. Continue to modify the settings as required. To return to the Diagnostics menu, press
Esc.
Canoga Perkins Corp. Ethernet 1G/10G Network Interface Device 29-AUG-2011
9145ELB-B83-0 V04.01 10:55:13
-------------------------- ETHERNET LOOPBACK SETUP------------------------------
Loop Test MAC Address: 00 40 2A 01 EE 11
1) Loopback State 10G Port 1 Loopback
2) Swap MAC Address
at Loopback Point? Yes
3) Recalculate CRC
at Loopback Point? Yes
Select [1-3]:
-----------------------------------------------------Messages---------------------------------------------------