Utilities
9145ELB NID Software User’s Manual
VT100 Baud Rate
79
7.4 VT100 Baud Rate
To change the VT100 baud rate, from the Utilities Menu, type 4 and press Enter. The baud rate
setting will be highlighted. Press the Space bar to select 9600 or 19200. Press Enter to confirm
the setting.
7.5 PING Generation
From the Utilities Menu, type 5 and press Enter. The PING Generation screen (Figure 7-3)
opens.
NOTE: PING Generation is also available from the Diagnostics Menu. See the chapter on Diag-
nostics for information on how to set up the Ping Generation screen.
Figure 7-3 PING Generation screen
Canoga Perkins Corp. Ethernet 1G/10G Network Interface Device 29-AUG-2011
9145ELB-971-4-0 V04.01 10:55:13
-------------------------------PING GENERATION---------------------------------
1) Ping to Address : 0.0.0.0
2) Ping from Address : Auto Selection
3) Ping Count : 0
4) Ping C-VLAN ID : 0
5) Ping T-VLAN ID : 0
6) Ping S-VLAN ID : 0
7) Ping Payload Size (40 - 9950) : 40
8) Ping DF Bit : Clear
9) Start Pinging
Select [1-9]
------------------------------------Messages-----------------------------------