3 swap bank after download and reset – CANOGA PERKINS 9145ELB NID Software Version 4.01 User Manual

Page 94

Advertising
background image

9145ELB NID Software User’s Manual

Software Upgrade

Swap Bank After Download and Reset

84

NOTE: All users will be logged off during the 9145ELB reset. In most cases, payload traffic
through the 9145ELB will be disrupted for only a few frames while the data plane is being repro-
grammed.

To swap banks and reset the 9145ELB, type 2 and press Enter. Swap will be highlighted. Press
Enter. The flash memory banks will be swapped and the 9145ELB will reset.

NOTE:The software on the new inactive flash memory bank will remain in memory and not be
deleted.

Figure 8-1 Software Upgrade screen

8.3 Swap Bank After Download and Reset

Option 3 allows you to select automatically swapping banks on reset after a successful
download. Select Yes for automatically swap banks. Select No to have downloaded software
remain in the inactive bank. This option does not generate a reset.

Type 3 and press Enter. Press the Space bar to select Yes or No.

NOTE: Users will be disconnected when the 9145ELB is reset.

The setting “Swap Bank after download and reset” must be set before downloading the new
software. After you download software, the message line will read Loads xx.xx on Next Reset.

Canoga Perkins Corp. Ethernet 1G/10G Network Interface Device 29-AUG-2011
9145ELB-971-4-0 V04.01 10:55:13
--------------------------------SOFTWARE UPGRADE-------------------------------

Time Since Last Restart 00:35:42

Version File Name File Size
Active Firmware 04.01 9145E-A50(GA0033)-04-00.ZIP 5494774
Inactive Firmware 03.50 9145E-A50(GA0021)-03-50.ZIP 5303334
Bootcode 03.10 9145E-B00(EB0033)-03-10.BIN 339094

1) Software Reset Reset
2) Swap Bank & Reset Swap
3) Swap Bank after
download and reset Yes

4) Get New File with TFTP
5) Hardware Reset HW Reset

Select [1-5]:

------------------------------------Messages-----------------------------------