VI DATA EXPORT ANALYSIS

The VISCPRO

®

VI Data Export Analysis

provides a convenient

operator interface for configuring Viscosity Index (VI) sample informa-
tion from the sample database for serial output and exporting it in ASCII
text format. The port output filters (Date, Sample and

Port Output

Format

) permit the user permit the user to select and output desired data

to a file, LPT port or serial port in whatever format is desired.

NOTE

Once the port output analysis has been generated, it cannot be
reconfigured like other VISCPRO

®

analyses. This prevents duplicate

data from being resent to network collection systems your lab may have
in place. To re-send data to the serial port, close the analysis window
(you may save the configured analysis if you desire) and then recreate
the analysis .

Available data for analysis

In addition to the serial transmission, the analysis displays requested
sample data on the computer screen in a tabular format and may include
the following data:

Smpl ID

—Sample ID for sample pair

VI

—Viscosity Index for sample pair

KV40C

—Kinematic viscosity at 40°C for low-temperature sample

KV100C

—Kinematic viscosity at 100°C for high-temperature sample

KV100F

—Kinematic viscosity at 100°F for low-temperature sample

KV210F

—Kinematic viscosity at 210°F for high-temperature sample

Avg KV 1/Avg KV 2

—Average measured kinematic viscosity (KV)

for the low/high temperature sample

Date 1/Date 2

—Date when the test was completed for the low/high

temperature sample

Time 1/Time 2

—Time when the test was completed for the low/

high temperature sample

Tube 1/Tube 2

—Tube serial number (S/N) for the low/high tem-

perature sample

Bulb 1/Bulb 2

—Bulb number (the bulb in which the sample was

run—#1 is the bottom bulb) for the low/high temperature sample

SUS 100F/SUS 210F

—Kinematic viscosity expressed in Saybolt

Universal Seconds (SUS) for the low/high temperature sample

TempC 1/TempC 2

—Bath temperature

TempF 1/TempF 2

—Bath temperature

Instr 1/Instr 2

—Instrument ID (from general configuration settings)

for the low/high temperature sample

InstrType 1/InstrType 2

—Instrument Type (from general configu-

ration settings) for the low/high temperature sample

Advertising