Parameter

#hex
/Sub#

Default

Brief Description (Note: Expanded description are
listed below)

100% rate

6032 None

This is the MAX RATE that the system can
achieve. Maximum rate is calculated from the rate
calibration data.

7 Rate Cal
Percentages

xx33

7 rate calibration percents.
Uses 2 decimal places. 0.00-100.00

0 Percent

0033

0.00

MIN percentage value required to start the feeder,
calculated from the other calibrated points.

1st Percent

1033

20.00

A 5 point auto-rate calibration ends at this value.
This is not used in a 2 point calibration

2nd Percent

2033

30.00

Fourth value to be run in a 5 point calibration or
the second value to be run in a 2 point calibration.

3rd Percent

3033

40.00

Third value to be run in a 5 point calibration. This
is not used in a 2 point calibration

4th Percent

4033

60.00

Second value to be run in a 5 point calibration or
the first point in a 2 point calibration

5th Percent

5033

80.00

A 5 point auto-rate calibration start at this
programmed value

100 Percent

6033

100.00

MAX percentage value = 100%

End Rate Calibration Section

ADC Average

34

None

0x0034 // Read Only

STATE 35

None

0x0035 // Read Only

Mode

Value

IDLE_MODE 0
AUTO_MODE 1
MANUAL_MODE 2
START_MODE 3
STOP_MODE 4
SHUT_OFFMODE 5
PAUSE_MODE

6

RATE_CAL_MODE 7
REFILL_MODE 8
FULL_MODE

9

MANUAL_HOLD_MODE

10

RATECAL_HOLD_MODE 11
INITIAL_REFILL_MODE

12

MANUALOP

37

None

Two decimal places. This it the output percent
when in MANUAL mode.

FAST_ROC

38

None

Lightly averaged rate of change, read only, RATE
decimal places.

zerocount 0x0A00

None

AD counts at zero weight

calLowCount 0x0A01

None

Numbers or letters in the titles below correspond to the values in Column 2, Hex#, above

Parameter 2

Metric (Unit of Measure)

The Unit parameter sets the scale and related displays to one of the following options: