51

Chapter 7

Output Percentage:
This is the value, in the range of 0 to 100 percent, representing the full motor speed
range. This is the value the user outputs to the feeder motor control to achieve the
requested rate of change.

Gross Weight:
This is the actual weight of the product still available in the feeder. Change in weight is
used to calculate the ROC and also establish refill points.

Setpoint:

This is the requested feed rate to be maintained.

Controller State:

This is an indication of the module current operating condition. This would include
states such as Auto mode, refill mode or shutdown as examples. The state indication,
along with the Controller Status, will give you real time indications of the condition of
your system and the unit’s feed rate control.

Version:

indicates the version of firmware in the module.

Controller Status:

This is the module condition or status. Status may show an A/D converter error, REC
status, Refill status and other faults. This, along with the Controller State, will provide
real time run condition indication and feed rate control.

Counter:

This is a constantly increment value. This can be used to verify communications.