Chapter 2 - Specifications

2-1

CHAPTER 2 - SPECIFICATIONS

A Brief Description of
Chapter 2

Chapter 2 lists the specifications for the HI 1769-WS
& HI 1769-2WS Weigh Scale Modules. Specifica-
tions are listed for the standard instrument and for
optional equipment. The specifications listed are
designed to assist in the installation, operation and
troubleshooting of the instrument. All service person-
nel should be familiar with this section before
attempting an installation or repair of this instrument.

Specifications for a
Standard HI 1769-WS
Weigh Scale Module

Maximum Installed
Modules

8 modules - per power supply in a single bank (Mod-
ule(s) must be installed within 4 slots on either side of
the power supply)

Channels

1 Channel

HI 1769-WS

2 Channel

HI 1769-2WS

Conversion Rate

100 updates per second

Averages

1-255 User Selectable in single increments

Resolution

Internal:

1:8,388,608

Input

Up to four (4) 350 ohm Full Wheatstone Bridge,
Strain Gauge Load Sensors/Cells (5 volt excitation)
on one vessel.

Non-Linearity

0.0015% of Full Scale

WAVERSAVER

®

User Selectable

4.00 Hz

2.00 Hz

1.00 Hz (Default)

0.50 Hz

0.25 Hz

OFF

Common-Mode
Rejection

120dB from 59 to 61 Hz