Chapter 4 - Setup

4-3

Setting Up
Communications
Between the
MicroLogix 1500
Processor and the

HI 1769-WS & HI 1769-
2WS Weigh Scale
Modules

NOTE:

On the side of the module you will see a label that
reads either Firmware REV A or Firmware REV
B,C,D etc. Both setup procedures are the same except
for the Connection Parameters/Extra Data Length.
For REV A the setting is 0. For all other REVs the set-
ting is 48.

To set up communication between the MicroLogix
1500 Processor and the Weigh Scale Module you will
need to do the following in RSLogix 500:

Step 1.

We assume you have a project open or
have created a new project. For instruc-
tions please see your RS LOGIX 500 man-
ual. The setup instructions begin from this
point.

Step 2.

From the I/O Configuration dialog box,
under “#” column heading click on #1 or
the next open slot number available. (See
Fig. 4-3)

FIG. 4-3 I/O CONFIGURATION DIALOG BOX