Chapter 2 - specifications, A brief description of chapter 2, Channels – Hardy HI 1756-2WS User Manual

Page 15: Conversion rate, Averages, Resolution, Input, Non-linearity, Waversaver, Excitation monitor

Advertising
background image

Chapter 2 - Specifications

2-1

CHAPTER 2 - SPECIFICATIONS

A Brief Description of
Chapter 2

Chapter 2 lists the specifications for the HI 1756-WS
and HI 1756-2WS Weigh Scale Modules. Specifica-
tions are listed for the standard instrument and for
optional equipment. The specifications listed are
designed to assist in the installation, operation and
troubleshooting of the instrument. All service person-
nel should be familiar with this section before
attempting an installation or repair of this instrument.

Specifications for a
Standard HI 1756-WS
(-2WS) Weigh Scale
Module

Channels

2 Channels

Single Channel HI 1756-WS

Dual Channel HI 1756-2WS

Conversion Rate

50 updates per second

Averages

1-255 User Selectable in single increments

Resolution

Internal:

1:8,388,608

Input

Up to eight (8) 350 ohm Full Wheatstone Bridge,
Strain Gauge Load Sensors/Cells (5 volt excitation)
on one vessel.

Non-Linearity

0.0015% of Full Scale

WAVERSAVER

®

User Selectable

7.50 Hz

3.50 Hz

1.00 Hz (Default)

0.50 Hz

0.25 Hz

Excitation Monitor

Current less than +/- 10% expected

Common-Mode
Rejection

110dB at or below 60 Hz