Chapter 4 - Setup

4-9

NOTE:

*Since the 1756 module has no real-time clock, the

operator must set the year, month, day, and calid.

9

DINT

Waversaver

Legal Values are 0-4
0 = 7.5 Hz
1 = 3.5 Hz
2 = 1 Hz
3 = .5 Hz
4 = 0.25 Hz

10

REAL

SpanWeight

Calibration weight, high, in lbs or kgs

11

REAL

CalLowWeight

Calibration weight, low, in lbs or kgs

12

DINT

NumAverages

Legal Values: 1-255

13

DINT

ZeroTrackEnable

Enable for Zero Tracking
Legal Values:
0 = Not Enabled
1 = Enabled

14

DINT

ROCTimeBase

Legal Values: 1-1800 seconds

15

REAL

ZeroTolerance

In lbs or kgs.

16

REAL

AutoZeroTolerance

In lbs or kgs

17

REAL

MotionTolerance

In lbs or kgs

#

Type

Parameter

Description

TABLE 4-1: PARAMETERS