Setting the span weight value, Setting the waversaver® value – Hardy HI 1756-2WS User Manual

Page 51

Advertising
background image

Chapter 4 - Setup

4-23

Setting the Span
Weight Value

The Span Weight is a reference point derived from an
actual measured weight. This should not be confused
with the Scale Capacity. If you have a 100 pound
weight and you place it on the scale, the Span Weight
would be 100 pounds.

Setting the

WAVERSAVER

®

Value

There are 5 selectable levels. 0 provides the least
vibration immunity with the fastest response time. 4
provides the most vibration immunity with the slow-
est response time. Default setting is 2.

Immunity

Setting

7.5 Hz

0

3.5 Hz

1

1.0 Hz

2

0.5 Hz

3

0.25 Hz

4

Advertising