Chapter 4 - Setup

4-7

FIG. 4-4 DISCRETE DATA

STATUSWORD bit positions refer to these variables:

Word

Number

Definition

ERRORADCONVERT

0x0001

Millivolt return from the load cell
system is out of range for the unit.

ERRORADFAILURE

0x0002

A/D converter in the unit is no
longer responding.

STATUSENGLISH

0x0004

Unit calibrated in lbs. If the bit is
off, calibrated in kgs.

STATUSZTRACK

0x0008

Auto Zero Tracking is turned on.

STATUSBUTTONENABLED

0x0010

Enabled/Disabled calibrate button.

STATUSINMOTION

0x0040

Weight is changing on the scale.

ERRORNOCAL

0x0080

The unit is at factory default set-
tings.

ERROREEPROMWRITE

0x0100

EEPROM Hardware Error

ERROREXCITEMON

0x0200

Excitation monitor error.

ERRORMAX144

0x0400

Hardware Error in Excitation
Monitor

STATUSCMDRCVD

0x2000

Output Table Command Complete