Common-mode voltage range, Backplane input voltage, Backplane current load – Hardy HI 1756-2WS User Manual

Page 16: Backplane power load, C2 calibration input, Cable lengths, Load cell excitation, C2 calibration output, Environmental requirements, Temperature coefficient

Advertising
background image

HI 1756-WS WEIGH SCALE MODULE

2-2

Common-Mode
Voltage Range

2.5VDC maximum (with respect to earth ground)

Backplane Input
Voltage

5 VDC and 24 VDC

Backplane Current
Load

<1 Amp at 5 VDC
0.0125 Amps at 24 VDC (with 4-350 Ohm Load Cells

Backplane Power
Load

< 5W at 5 VDC
< .3W at 24 VDC with 4-350 Ohm Load Cells

C2 Calibration
Input

Isolation from digital section 1000 VDC minimum.

Cable lengths

1000 feet maximum of C2 authorized cable
250 feet maximum of C2 authorized cable (Maximum
of 4 load sensors) with IT Junction box.

Load Cell
Excitation

5 VDC +/- 1.15 W maximum.
Isolation from digital section 1000 VDC minimum

C2 Calibration
Output

Isolation from digital section 1000 VDC minimum

Environmental
Requirements

Temperature
Coefficient

Less than 0.005% of full scale per degree C for Cal-
LO and Cal-HI reference points

Operating
Temperature
Range

0

o

C to 60

o

C (32

o

F to 140

o

F)

Storage
Temperature
Range

-40

o

C to 85

o

C (-40

o

F to 185

o

F)

Humidity Range

0-90% (non-condensing)

Approvals

CE Approval
UL, CUL (pending)

Digital Voltmeter

Accuracy +/- 2% of full scale
Resolution