HI 1756-WS WEIGH SCALE MODULE

3-4

Installing the Module I/
O Connector

About the Module
I/O Connector

The I/O Connector at the front of the module connects
the module to the Remote Terminal Assembly (-
RTA), a load sensor, or the HI 215IT Series Junction
Box, depending on how many load sensors are
installed in the weighing system. See below for the
pin-out diagram, which is also located on the inside of
the module door. (See Fig. 3-4 & 3-5)

Step 1.

Open the Module door to gain access to
the I/O connector. (See Fig. 3-4 & 3-5)

Step 2.

Install the cable and connector so it allows
the module door to be shut.

Step 3.

With the plug oriented correctly (See the
pin-out diagram above), plug the I/O male
connector into the I/O connector at the
front of the module.

Step 4.

Verify that the connector is completely
plugged in before operating the module.

NOTE:

Most problems are due to loose connections. Be sure
to check the I/O connection first if you have a problem

Single Channel

Dual Channel

Pin 1

Exc+

Pin 2

Sense+

Pin 3

Sig+

Pin 4

Sig-

Pin 5

Sense-

Pin 6

Exc-

Pin 7

C2+

Pin 8

C2-

Pin 9

Shield

Pin 1

Exc+

Pin 2

Sense+

Pin 3

Sig+

Pin 4

Sig-

Pin 5

Sense-

Pin 6

Exc-

Pin 7

C2+

Pin 8

C2-

Pin 9

Shield

Pin 10

Exc+

Pin 11

Sense+

Pin 12

Sig+

Pin 13

Sig-

Pin 14

Sense-

Pin 15

Exc-

Pin 16

C2+

Pin 17

C2-

Pin 18

Shield

Advertising