Write Non-Volatile

Command
(WRITENONVOL
ATILE)

The Write Non-Volatile Command causes all parame-
ters (including calibration constants) to be saved to
the non-volatile memory.

Command Number: 4 (Hexadecimal)
Channel Number: 0 or 1
Number of Elements: 8

Error Return Values: None

Reload Non-
Volatile
(RELOADNONVOL
ATILE)

The Reload Non-Volatile Command causes the weigh
module to re-read the values stored in its non-volatile
memory. Any parameters changed since the last write
non-volatile command are overwritten. this command
can be used to abort a calibration or parameter entry
session.

Command Number: 0x10 (Hexadecimal)
Channel Number: 0 or 1
Number of Elements: 8

Error Return Values: None

Enable Calibration
Button Command
(ENABLEBUTTON
CMD)

The Enable Calibration Button Command activates
the calibration button.

Command Number: 20 (Hexadecimal)
Channel Number: 0 or 1
Number of Elements: 8

Error Return Values: None

Disable
Calibration Button
Command
(DISABLEBUTTON
CMD)

The Disable Calibration Button Command deactivates
the calibration button.

Command Number: 40 (Hexadecimal)
Channel Number: 0 or 1
Number of Elements: 8

Error Return Values: None

Set Default
Parameters
(SETDEFAULTPAR
AMS)

Load the default settings into RAM, and non-volatile
RAM.

Command Number: 0x94 (Hexadecimal)