Configuration parameters for the hi 1765-ws module – Hardy HI 1756-2WS User Manual

Page 32

Advertising
background image

HI 1756-WS WEIGH SCALE MODULE

4-4

Configuration
Parameters for the HI
1765-WS Module

With version 2.3 software, the HI 1765-WS module
can recieve 32 words of the configuration data from a
PLC upon power-up. These data are used only if the
value for Config_rev_num is set to 1 and the parame-
ters are sent in the correct format and range.

NOTE:

DINT Parameters can be interpreted as floating point
based on the value of a bit within the DecimalPoints
parameter of the channel.

Parameter

Offset (In

Words)

Single Channel

Config_rev_num0 *

0

ChanEnabled0

1

DecimalPoints0 **

2

Metric0

3

NumAverages0

4

Waversaver0

5

SpanWeight0

6

CalLowWeight0

7

ZeroTrackEnables0

8

AutoZeroTolerance0

9

MotionTolerance0

10

TareWeight0

11

EnableButton0

12

RocTimeBased0

13

ZeroTolerance0

14

Spare1_0

15