Read status of module (getstatus), Write parameters (writeparam) – Hardy HI 1756-2WS User Manual

Page 46

Advertising
background image

HI 1756-WS WEIGH SCALE MODULE

4-18

Return Data:

• COMMAND

• CHANNEL

• STATUS

• 9 DINT SERIAL NUMBER

Error Return Values:

• OUTOFTOLERANCE - No C2 Sensor found.

Read Status of
Module
(GETSTATUS)

Reads the condition of the module.

Command Number: 0x80 (Hexadecimal)
Channel Number: 0 or 1
Number of Elements: 8

NOTE:

See the Timed Out Command section.
Return Data:

• COMMAND

• CHANNEL

• STATUS - Returns status of the last timed out

command.

Write Parameters
(WRITEPARAM)

Writes all the parameters.

Command Number: 0x68 (Hexadecimal)
Channel Number: 0 or 1
Number of Elements: 84

Return Data:

• COMMAND

• CHANNEL

• STATUS - The status is 0 if the command suc-

ceeded. If there was a range error detected in one
of the parameters, a non-zero value is returned
indicating which parameter failed its range. (See
Table 4-1)

Advertising
This manual is related to the following products: