Hardy HI 2151/30WC Single-Scale Controller User Manual

Page 28

Advertising
background image

HI 2151 Series Weight Controller
Profibus Interface Option

22

Block Read Data Number 24: Set Point Relay Status 5-6

Byte Definitions

Byte Pos.

#

Words

Start Word # Bytes Start Byte

Block Read Number 24 (Hex 18)

Set point Status on/off (See Paragraph 4.7.1)

Set point Description #5
Set point Description #6

Set point Value #5
Preact Value #5
Dead band Value #5

Set point Value #6
Preact Value #6
Dead band Value #6

Total Words/Bytes

LSB

MSB

LSB

MSB



1



1


2
2
2

2
2
2

14

0



1


2
4
6

8

10
12

1

1

1
1

4
4
4

4
4
4

28

0

1

2
3

4
8

12

16
20
24

Block Read Data Number 23: Set Point Relay Status 7-8

Byte Definitions

Byte Pos.

#

Words

Start Word # Bytes Start Byte

Block Read Number 25 (Hex 19)

Set point Status on/off (See Paragraph 4.7.1 )

Set point Description #7
Set point Description #8

Set point Value #7
Preact Value #7
Dead band Value #7

Set point Value #8
Preact Value #8
Dead band Value #8

Total Words/Bytes

LSB

MSB

LSB

MSB



1



1


2
2
2

2
2
2

14

0



1


2
4
6

8

10
12

1

1

1
1

4
4
4

4
4
4

28

0

1

2
3

4
8

12

16
20
24