Section 7: Selectable Writes

47

Example Output from the server:

Byte

Hex#

Description

Byte 0

53

Block Write Number

Byte 1

00

Unused

Byte 2

42

Decimal Point Position (66)

Byte 3

00

Number ignored

Byte 4

03

3 Decimal Places

Byte 6

3C

Tare Value

Byte

Hex#

Description

Byte 7

00

Number ignored

Byte 8

00

Tare Value = 100 (hex)

Byte 9

00

Byte 10 01

Byte 11 00

7.6

OPERATOR SELECTABLE WRITE EXAMPLE

1. The following example is a setup to download set point #1 and #2 values (without

preacts and dead bands).

NOTE:

Any set point value can be entered into K memory.

When C1 is activated the Move Word (MOVW1) downloads the information to the weight
controller using WY17 through WY31.

K1: Contains hex 5300 (Selects Block Write #83)

K2: Contains hex 1800 (Selects parameter #24 - Set point number 1)

K3: Contains Double 790 (Sets set point 1 to 790)

K5: Contains hex 1B00 (Selects parameter #27 - Set point number 2)

K6: Contains Double 800 (Sets set point 2 to 800)

C1: Starts the program

MOVW1: Downloads the information in K1-K7 into WY17-WY23 (weight controller)