Block write command numbers – Hardy HI 2151/30WC Single-Scale Controller User Manual

Page 35

Advertising
background image

Section 5: Block Writes

29

C1: Starts the program

MOVW1: Downloads the information in K1-K14 into WY17-WY31 (weight controller)

5.6

BLOCK WRITE COMMAND NUMBERS

Block Write Command Number 70: Activate Scale Functions

Byte Definitions

Byte
Pos.

#

Words

Start Word # Bytes Start Byte

Block Write Number 70 (Hex 46)
Activate by setting remote functions bit to 1 then
reset to 0

TARE = Current Gross Weight
Initiates print on standard RS232
Add current net weight to Total
Clear Peak Hold
Clear Totalizer Accumulator
Zero the Instrument
Enable Zero Tracking (blind unit only)
Reserved for future use

Total Words/Bytes

LSB

MSB

bit 0
bit 1
bit 2
bit 3
bit 4
bit 5
bit 6
bit 7

1








1

0










1

1







1

0

1

Block Write Command Number 71: Force Relay Status

Byte Definitions

Byte
Pos.

#

Words

Start Word # Bytes Start Byte

Block Write Number 71 (Hex 47)
Activate by setting remote functions bit to 1 then
reset to 0

Relay 8
Relay 7
Relay 6
Relay 5
Relay 4
Relay 3
Relay 2
Relay 1

Total Words/Bytes

LSB

MSB

bit 0
bit 1
bit 2
bit 3
bit 4
bit 5
bit 6
bit 7

1









1

0

1

1







2

0

1


Advertising