HI 2151 Series Weight Controller
Profibus Interface Option

24

Block Read Data Number 29: Sticker Value

Byte Definitions

Byte Pos.

#

Words

Start Word # Bytes Start Byte

Block Read Data Number 29 (Hex 1D)

Reserved for future use


Sticker Value

Total Words/Bytes

LSB

MSB

1


2

3

0


1


1
1

4

6

0
1

2

Block Read Data Number 30: Configuration of Rate-of-Change

Byte Definitions

Byte Pos.

#

Words

Start Word # Bytes Start Byte

Block Read Number 30 (Hex 1E)

Reserved for future use


Displayed Rate-of-Change time
(0 = Sec, 1 = Min, 2 = Hrs)
Rate-of-Change time base evaluation period in seconds

Time base evaluation period:
0 = 1 second

5 = 6 seconds

10 = 60 seconds

1 = 2 seconds

6 = 10 seconds 11 = 120seconds

2 = 3 seconds

7 = 12 seconds 12 = 240seconds

3 = 4 seconds

8 = 15 seconds 13 = 450seconds

4 = 5 seconds

9 = 30 seconds 14 = 900seconds

15 = 1800 secs


Total Words/Bytes

LSB

MSB


LSB
LSB

1



1
1









3

0



1
2

1
1


2
2









6

0
1


2
4

Block Read Data Number 31: Configuration of Analog Output

Byte Definitions

Byte Pos.

#

Words

Start Word # Bytes Start Byte

Block Read Number 31 (Hex 1F)

Weight Parameter (Value)

0 = Gross
1 = Net
2 = Rate-of-Change
3 = Peak Hold
4 = Total Weight


Wt Value is a Zero Scale Analog Output
Weight Value is a Full Scale Analog Output

Total Words/Bytes

LSB

MSB




1








2
2

5

0








1
3

1

1






4
4

10

0

1






2
6