Configuration of analog output, Configuration of standard rs232 port – Hardy HI 2151/30WC Single-Scale Controller User Manual

Page 56

Advertising
background image

HI 2151 Series Weight Controller
Profibus Interface Option

50

7.7.6

CONFIGURATION OF ANALOG OUTPUT

Configuration of Analog Output

#

Words

#

Bytes

Parameter

#

Hex #

Weight Parameter (Value)

0 = Gross
1 = Net
2 = Rate-of-Change
3 = Peak Hold
4 = Total Weight

Weight Value Represented by a Zero Scale
Analog Output

Weight Value Represented by a Full Scale Analog
Output

0.5

2

2

1

4

4

85

86

87

55

56

57

7.7.7

CONFIGURATION OF STANDARD RS232 PORT

Configuration of Standard RS 232Port

#

Words

#

Bytes

Parameter

#

Hex #

Format of Printout

Print Initiation (0 = Continuous, 1 =Altered
print)*
Set point, Dead band and Preact
Rate-of-Change
Tare Weight
Net Weight
Gross Weight
Print Initiation (0 = Continuous, 1 = Altered
print)
Reserved for future use (must be set to 0)

Baud Rate (0 = 600, 1 = 1200, 2 = 2400, 3 = 4800,
4 = 9600,5 = 19200)

Port Configuration (must be set to for printer
output only)

Stop Bits (0 = one stop bit, 1 = two stop bits)

Parity (0 = none, 1 = even, 2 = odd)

Handshake Control (0 = hardware, 1 = software)

Word Length (0 = seven bits, 1 = eight bits)

Device Address (a value from 0-99)

Echo (0 = off, 1 = on)

bit 0

bit 1
bit 2
bit 3
bit 4
bit 5
bit 6

bit 7

0.5

0.5

0.5

0.5

0.5

0.5

0.5

0.5

0.5

1

1

1

1

1

1

1

1

1

90

91

92

93

94

95

96

97

98

5A

5B

5C

5D

5E

5F

60

61

62

7.7.8

WAVERSAVER & EXCITATION MONITOR (HI 2151/30WC ONLY)

WAVERSAVER and Excitation Monitor

#

Words

#

Bytes

Parameter

#

Hex

Number

WAVERSAVER (1-5)

Excitation Monitor

0.5

0.5

1

1

99

100

63

64