HI 2151 Series Weight Controller
Profibus Interface Option

52

8.3

TROUBLESHOOTING GUIDE

8.3.1

LED DOES NOT COME ON (SEE FIG. 8-1)

TROUBLE

PROBABLE CAUSE

REMEDY

LED does not come on.

No power to the board.

Check powercord to see if it is
plugged in or broken.

Check power source to see if
there is power to the outlet.

Figure 8-1

8.3.2

SELF TEST FAILS

TROUBLE

PROBABLE CAUSE

REMEDY

PLFAIL
Message

System failed
the loop back
test.

PROFIBUS PCB is
plugged in incorrectly.

Remove the PROFIBUS PCB
and reinstall the card being
careful to be sure that the pins
are not bent or in the wrong
slots on the connector.

PRFAIL
Message

System failed
the RAM test.

SPC-3 (PROFIBUS) chip
has failed.

NOTE: Loop-back test

passes but the
ram test fails

Replace the PROFIBUS
Interface Card.

Contact Hardy Process
Solutions, Customer Service
Department for Instructions.