Hardy HI 2151/30WC Single-Scale Controller User Manual

Page 61

Advertising
background image

Section 8: Troubleshooting

55

32

8

Reserved for future use

33

12

1

81

51

Tare value exceeds legal range
of -99,999-999,999

34

2

82

52

Units of measure are
0=Pounds/1=Kilograms

35

3

Reserved for future use

36

4

85

54

Totalizer decimal point must be
equal or less than decimal point
position (0-4)

37

5

85

55

C2 load cell count must be
between 0-8

38

6

86

56

Sticker value must be a 6 digit
number (between 65536-
999999)

39

7

87

57

Analog out should be -99,999
and 999,999

40

8

88

58

Analog low count can’t equal
high count

41

13

1

89

59

Scale in Calibration Mode*

42

2

101

Invalid WAVERSAVER

43

3

Reserved for future use

44

4

96

60

Load cell count error

45

5

97

61

No C2

®

load cells found

46

6

98

62

Load cell capacity/sensitivity
error

47

7

99

63

Load cell checksum error

48

8

100

64

Too many significant digits after
the decimal to be displayed

TABLE 8-1 RESPONSE/ERROR CODES

NOTES:

Writes are not allowed while scale is in calibration mode.

The first 6 bytes of the diagnostic information is reserved as defined in the Profibus
Standard. Bytes 7-13 are used by the HI 2151 Series -B12 PROFIBUS interface option to
provide automatic response/error codes.

8.4

CLEARING PROFIBUS DIAGNOSTIC CODE ASSOCIATED BIT(S)

1. A separate bit is reserved for each response/error code. When a response/error occurs, an

associated bit will be set to 1. This bit will remain set to 1 until it is cleared.

2. Clearing the error/code associated bit procedures.

a. Operator Selectable Transfer, rerun the Write “0" command.

b. Block Transfer, request the Read Block #90 via a Block Write 24 with data 90.