Chapter 2 Quick Guide to Basic Mode Operation

2

17

4) Press the

or

key to display the desired value.

Pressing the

key changes the flashing digit to the right.

Pressing the

key changes the value.

All digits flash when the fifth digit and sign can be changed.

Example

When setting the tolerance to +20

µm, specify “0020”.

5) Press the

key.

The HIGH limit setting value is saved. The sensor automatically enters the
LOW limit value setting mode.

8. Set the lower value for the tolerance limit and press the

key.

For a press, set the threshold value to the amount of the lowering of the
bottom dead center due to the absence of a target.

Set the LOW limit value using the same procedure as in steps 7 3) and 4),
and press the

key to save the value.

Note 1: The output is disabled during the tolerance limit value setting. When the
output is already on, however, the output is retained.

Note 2: Pressing the

key does not save the changes if [HIGH setting value –

Hysteresis] is smaller than [LOW setting value + Hysteresis]. In this case, “Err1” is
displayed. Press the

key again to cancel the error, and then specify the correct

values.

HIGH

TIM

GO

LOW

HIGH

TIM

GO

LOW

HIGH

TIM

GO

LOW

No setting

(5th digit)

(1st to 4th digits)

Stripper or upper die

Die set