Chapter 4 Use of Data Processing Functions

4

50

Simple bottom-dead-center measurement function (Internal trigger) [b-0]

Measures the "minimum value" detected during a specified period.

*

The external trigger mode is not available for the simple bottom-dead-center measurement. For the
internal trigger setting, only a trigger level and trigger hysteresis can be specified.

If a comparator output disable input turns ON before the comparator operation,
the comparator output does not turn ON.

The trigger level is factory-adjusted to the full scale.

Turning the strobe output from ON to OFF results in the off-delay of 2 ms for
updating the comparator output.

Limited bottom-dead-center measurement function [b-1]

Measures the "minimum value" detected during a specified period (sampling
period).
For the limited bottom-dead-center measurement function, the sampling period can
be specified with the combination of the trigger mode and delay time settings.

➮ For the details of the trigger mode and delay time, refer to pages 53 to 55.

Timing diagram

External trigger mode

If a comparator output disable input turns ON before the comparator operation,
the comparator output does not turn ON.

The sampling period is between the UP edge of the timing input (hold-reset
input) and the UP edge of the next timing input. The value measured at the
instant when the timing input turns ON is displayed/output.

Reference: To clear the measured value being held and to start the measurement
again, short-circuit the hold-reset and GND terminals.

(t)

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

0

When the power is turned ON or the hold-reset signal is input,
the display shows " " until the first timing signal is input.

Displayed value

POWER ON or
Reset input

Strobe output
HIGH OUT
HI
GO OUT
GO
LOW OUT
LO
Comparator
output disable input

Bottom-dead-center values

Trigger level

(t)

0

ON

OFF

When the power is turned ON or the hold-reset
signal is input, the display shows " " until
the first measured value is determined.

Displayed value

Timing input

Limited bottom-dead-center values

Sampling period

Sampling period

Sampling period