Chapter 2 Quick Guide to Basic Mode Operation

2

20

Reference: Four kinds of tolerance limit values ("0" to "3") can be saved in the
memory. The registered setting numbers can be switched using external signals
(

➮ page 4).

3) Press the

key.

• The sensor automatically enters the HIGH limit value setting mode.
• The setting value is displayed in red and the HIGH indicator illuminates.

4) Press the

or

key to display the desired value.

• Pressing the

key changes the flashing digit to the right.

• Pressing the

key changes the value.

• All digits flash when the fifth digit and sign can be changed.

5) Press the

key.

The HIGH limit setting value is saved. The sensor automatically enters the
LOW limit value setting mode.

6) Press the

key again.

7. Activate the machine to check whether the comparator output correctly works

according to the tolerance limit setting values.

The GO comparator output indicator on the controller illuminates when the
measured value is within the tolerance range. The HIGH indicator illuminates
when the measured value is higher than the upper limit value. The LOW
indicator illuminates when the measured value is lower than the lower limit
value.

To perform fine adjustment of the tolerance limit values, repeat steps 5) and
6) described above.

HIGH

TIM

GO

LOW

HIGH

TIM

GO

LOW

No setting

(1st to 4th digits)

(5th digit)

HIGH

TIM

GO

LOW