Chapter 4 Use of Data Processing Functions

4

58

5. Follow one of the procedures below according to the selected function number:

● When "b-0" or "b-1" is selected:

Press the

key.

The sensor saves the setting and returns to the measurement state.

● When "b-2" (Difference between peaks [bottoms] measurement) is selected:

1) Select "b-20" or "b-21" and then press the

key to confirm the selec-

tion.

"b-20": Difference between peak values measurement
"b-21": Difference between bottom values measurement

2) Specify the hysteresis to determine the peak (bottom) value as neces-

sary.

3) Press the

key.

The sensor saves the setting and returns to the measurement state.

Note 1: The hysteresis can be set within the range of 0 to 19.999.

Note 2: The hysteresis is factory-adjusted to 10 digits.

Simple difference measurement function [b-0]

Measures the difference between the maximum and minimum values detected
during a specified period (sampling period).

For the simple difference measurement function, the sampling period can be
specified with the combination of the trigger mode and delay time settings.

➮ For the details of the trigger mode and delay time, refer to pages 61 to 63.

Timing diagram

External trigger mode

The sampling period is between the UP edge of the timing input (hold-reset
input) and the UP edge of the next timing input.

The value measured at the instant when the timing input turns ON is displayed/
output.

Reference: To clear the measured value being held and to start the measurement
again, short-circuit the hold-reset and GND terminals.

(t)

0

ON

OFF

p

b

p'

b'

(p-b)

(p'-b')

Displayed value

Timing input

Simple difference
value

Sampling period

Sampling period

When the power is turned ON or the hold-reset
signal is input, the display shows " " until
the first timing signal is input.