Chapter 2 Quick Guide to Basic Mode Operation

2

23

4) Press the

or

key to display the desired value.

Pressing the

key changes the flashing digit to the right.

Pressing the

key changes the value.

All digits flash when the fifth digit and sign can be changed.

5) Press the

key.

The HIGH limit setting value is saved. The sensor automatically enters the
LOW limit value setting mode.

6. Set the lower value for the tolerance limit.

Set the lower limit value.

Use procedures 3) and 4) in step 5 to set the LOW limit value. Then, press
the

key to save the value.

Note 1: The output is disabled during the tolerance limit value setting. When the
output is already on, however, the output is retained.

Note 2: Pressing the

key does not save the changes if [HIGH setting value -

Hysteresis] is smaller than [LOW setting value + Hysteresis]. In this case, "Err1" is
displayed. Press the

key again to cancel the error, and then specify the correct

value.

Reference: When the thickness/gap mode is selected, in the initial setting state the
measured value becomes larger as the distance between the sensor head and
target is shorter. When you want to make the measured value smaller as the
distance is shorter, set function "d" (inverse/normal display function) to normal.
For details, see page 73.

HIGH

TIM

GO

LOW

No setting

(5th digit)

(1st to 4th digits)

HIGH

TIM

GO

LOW

Direction in which the
measured value increase