Chapter 4 Use of Data Processing Functions

4

47

4.2

Details of Bottom-dead-center Mode

This section describes function codes "A" to "d" specified with the

key for the

bottom-dead-center mode.

4.2.1 No. of averaging measurements/Digital filter [A]

Sets the number of averaging measurements or the digital filter function.

No. of averaging measurements function

You can specify the number of averaging the measured signals input from the
sensor head. This function is effective to ignore sporadic changes or to obtain
quick comparator output.

Digital filter function

You can display the signals input from the sensor head by eliminating the
signals higher than a specified frequency. This function is effective to ignore
abrupt fluctuations and to obtain a smooth curve display.

Setting function "A"

1. Press the

key for at least 2 seconds.

The sensor enters the common function selection mode.

2. Check that "A" flashes.

3. Press the

or

key.

The function number for the No of averaging measurements or the digital filter is
displayed.

4. Press the

key to select the desired function number.

Pressing the

key changes the function number sequentially.

Pressing the [ZERO] key resets the display to "A-A0".

5. Press the

key.

The sensor saves the setting and returns to the measurement state.

SET

CALL

HIGH

TIM

GO

LOW

FUNC

UTILITY

MODE

CALIB