While viewing the gross weight in Run Mode, pressing the Enter Key toggles the display between bar graph and
numerical display. Follow this procedure to modify Bargraph Span:

1. If the SVS2000 is in Run Mode, press the ‘1’ Key, ‘4’ Key, and Enter Key to access the menu tree. The

display shows:

14 BArgrAPH SPAn

2. Press the enter key to access this menu. The display looks like this:

> 9999 lbs

(Units are consistent with Disp Units.)

3. Use the numeric or Arrow Keys to enter the desired value. Press the Enter Key to save the value in

memory. The display acknowledges the entry and returns to:

14 BArgrAPH SPAn

4. Press an Arrow Key to scroll to another menu or press the Gross or net Key to return to Run Mode.

ModIFyIng dISp (dISplay) ForMaT and dISp (dISplay) unITS

If you modify Disp Format and/or Disp Units, you may need to modify other parameters as well. Changing Disp
Format moves the decimal place for all parameters based on it. Changing Disp Units changes the units for all
parameters based on it. The SvS2000 does not ‘convert’ parameter values based on changes in units — it
simply changes the name of the unit. Below are the parameters that are affected by changes to DispFormat or
Disp Units. If you are not using or have not yet set up a function (for example, you have not set up digital outputs
yet), the changes will not affect the operation of the system. Before you change Disp Format and/or Disp units,
record the values for each of the parameters that may change with Disp Format or Disp Units.

Example 1. Change Disp Format from xxxxxx00 to xxxxxx

record current parameter values:
Disp Format = xxxxxx00
Scale Factor Weight = 100,000
Relay1 Value = 90,000 (dummy zeroes underlined)
Change Disp Format. As a result of the change, the parameter values change to:
Scale Factor Weight = 1,000
Relay1 Value = 900
re-enter parameter values:
Scale Factor Weight = 100,000
Relay1 Value = 90,000

Parameters Affected By Changes To Disp Format or Disp units

Bargraph Span [14]
Scale Factor Weight [22]
Linearize Set [23]
Zero Tolrance [24]
Relay and Digout Value, Deadband, and

Advertising