29 cal (calIBraTIon) dISplay

Accessing this menu allows you to view the calibration values that have been entered or internally calculated, as
shown in Table4. Follow this procedure to display the calibration parameters:

1. If the SVS2000 is in Run Mode, press the ‘2’ Key, ‘9’ Key, and Enter Key to access the menu tree. The

display shows:

29 CAL DISPLAy

2. Press the enter key to access this menu. The display looks like this:

Cnt/mV 699

3. Press the Arrow Keys to scroll through the other calibration display parameters.

4. Press the Gross or net Key to return to Run Mode.

Table 4. Calibration Display

Calibration Parameter

Description

Cnt/mV

digital counts per millivolt of signal

ScfWgt 1

scale factor weight

[entered scale factor weight

from Manual Cal

or

(hi span weight - lo span weight)

from Auto Cal]

ScfCnt 1

scale factor counts

[entered scale factor counts

from Manual Cal

or

(hi span counts - lo span counts)

from Auto Cal]

ZeroCnt

zero counts = digital counts

corresponding to zero weight

DispVCW 2

entered display value

correction weight

HiSpanW 2, 3

entered hi span weight

LoSpanW 2, 3

entered lo span weight

HiSpanC 2, 3

hi span counts = digital counts

corresponding to hi span weight

LoSpanC 2, 3

lo span counts = digital counts

corresponding to lo span weight

0mV_Cnt

digital counts corresponding

to 0 millivolts of signal