23 Linearization

Linearize Set2 —

1In — 0 1Ot — 0

2In — 2,500 2Ot — 2,500

3In — 5,000 3Ot — 5,000

4In — 7,500 4Ot — 7,500

5In — 10,000 5Ot — 10,000

Linearize enable — OFF

24 Zero Tolrance2 — 100

30 Setpoint Menu

31-38

Relay #1 and #2,

Digital Outputs #1 through #6

value — 0

Deadband2 — 10

Hi/Lo — Lo

Track — grs

Fail-Safe — Off

Preact — 0

40 I-Output Menu

41 IOut range — 4-20mA

42 IOut: 4/0mA2 — 0

43 IOut: 20mA1, 2 — 9999

44 IOut Track — grs

45 IOut Failsafe — Lo

46 IOut enable — Off

48 Current Adjst

0mA Point — 910 cts

4mA Point — 3,600 cts

20mA Point — 14,516 cts

50 Com Menu

51 Serial Addres — 255 decimal/FF hex

52 Serial Baud — 9600

60 Sensor Menu

61 Sensor Adj ex1 — 12 v

62 resolution — 21bt

63 Sensor gain1 — 2

70 Filter Menu

71 Averaging — 1

72 DSP enable — On

73 DSP Step2 — (based on 10,000 counts)

74 DSP Qualify — 3

75 DSP Factor — 100%

80 Tracking Menu

81 rate Threshld2 — (based on ±10 uv/sec)

82 Sample Intrvl — 10 seconds

83 Zero Trak Win2 — 0

84 Drift Limit2 — (based on ±5 mv)

85 mat Trak enab — Off

90 Service Menu

91 user Access — (no code needed)

92 keyboard Lock — (no code needed)

notes:

1 Values for these parameters may have changed

as a result of Quick Config entries and/or
internal calculations based on those entries.

2 Values for these parameters are consistent with

Disp Format. For example, if Disp Format is
xxxxxx, Zero Tolrance is 100. If Disp Format
is xxxxxx00, Zero Tolrance is 10,000. If Disp
Format is xxxxx.x, Zero Tolrance is 10.0.

Advertising