E.6.9 mgf trigger – Haltech E6X Manual DOS Version User Manual
Page 127
Advertising
E6X Manual
127
E.6.9 MGF Trigger
The 4-cylinder MG-F uses a unique trigger system similar to that of the Subaru engines. This
trigger system uses use a crank-angle trigger system. Select the Trigger type as “MGF” and
connect the Crank angle sensor to the Trigger Input. The Trigger Input should be set to
Reluctor and the “Trigger angle” should be approximately 65
±
2° BTDC.