Cable requirements

Table 3 lists the requirements for the cables that connect to the dome.

Note: When using UTP cable for video and data, the wires can share the same jacket but must remain separate twisted pairs.

Power cable size and length requirements

Using the proper gauge of power cable will ensure proper operation and avoid voltage drops. See Table 4 for
the recommended cable gauge for varying maximum cable lengths and power draws.

Table 3.

Cable requirements

Operation

Cable requirement

Length

feet

meters

Data

For RS-422: 22 gauge (0.64 mm) unshielded, two-conductor, twisted-pair (UTP)
cable

10,000

3,000

For RS-485: 22 gauge (0.64 mm) shielded, two-conductor, twisted-pair (STP) cable

3,000

900

Video

75 ohm coaxial cable (RG59 with lift/gain)

1,600

486

22 gauge (0.64 mm) unshielded, two-conductor, twisted-pair (UTP) cable

Note: Use only crimp-on BNC connectors. Do not use screw-on connectors.

1,250

381

Alarm

Cat-5 cable (recommended)

1,250

381

Relay contacts

Cat-5 cable (recommended). Contacts rated for 60 W DC, 62.5 W AC with 2 A max.

1,250

381

Power

24 VAC cable. To determine the size of cable needed for individual applications, see

Power cable size and

length requirements

.

Table 4.

Recommended power cable gauges based on maximum lengths for an operating voltage of 24 VAC (±4 VAC)

Wire gauge

Domes with fan (20 VA)

Domes with

12 W heater/fan (x2) (45 VA)

HD domes with

23 W heater/fan (x2) (66 VA)

AWG

mm (dia.)

feet

meters

feet

meters

feet

meters

10

2.60

1569

478

784

238

490

149

12

2.05

988

301

494

150

309

94

14

1.62

620

188

310

94

194

59

16

1.29

391

119

196

59

122

37

18

1.02

246

74

123

37

77

23

WARNING: Be aware that the power requirements for CyberDome II and CyberDome are different, which may require