CyberDome II can use different protocols for communication. To select a protocol, you must set the protocol
DIP switches to the correct sequence of 1s (on) and 0s (off).

To set the protocol DIP switches to select a protocol, do the following:

1. Locate the protocol DIP switch block (Figure 23 on page 26).

2. Using Table 6, find the DIP switch sequence for the desired protocol and set the switches accordingly.

CyberDome II stores programming settings in NVRAM in both the housing and the PTZ module. If the
protocol switches are not set to one of the copy settings (01111 or 11111) and the two memories are different,
Memory flashes onscreen. When you first log onto the menu system, you will be asked which settings you
would like to use. For more information on protocol functionality with the CyberDome II camera, see
Appendix B,

Protocol functionality

on page 49

Table 6.

Protocols

Protocol

Switch position

a

a.

1 = on, 0 = off.

Protocol

Switch position

a

Automatic selection

b

b.

The Automatic selection will automatically determine only the GE protocols (Digiplex, Impac, and ASCII).

00000

AD RS-422

01010

GE Digiplex RS-422 4800

10000

AD Manchester

10010

GE Impac RS-485 9600

01000

Bosch RS-232

00110

GE ASCII RS-422 9600

11000

Bosch biphase

10110

Pelco D autobaud

00100

Coaxitron

11110

Pelco P autobaud

10100

KD6

10001

Ultrak 9600

01100

Serial update 9600

11011

BBV

01110

Serial update 115200

00111

VCL

11100

Clear settings

10111

Panasonic

11010

Copy settings from PTZ to housing

01111

Vicon

00010

Copy settings from housing to PTZ

11111