Setting the camera’s address – Interlogix UltraView PTZ Dome Series User Manual

Page 36

Advertising
background image

CyberDome II

Installation Manual

28

Setting the camera’s address

To set the DIP switches to indicate a site number, do the following:

1. Locate the site address DIP switch block (Figure 23).

2. Using Table 7, determine which DIP switches when turned on will add up to the site number for the

camera and set those switches to the on position. See Figure 24 for an example.

3. Place the switches that correspond to those values in the on position.

Figure 24. Address DIP switches (set to 210: 128 + 64 + 16 + 2)

Table 8 on page 29 shows the DIP switch settings for cameras 1 through 64.

Table 7.

Dip switch positions and equivalent values

DIP switch position number

1

2

3

4

5

6

7

8

9

10

11

12

Equivalent value

1

2

4

8

16

32

64

128

256

512

--

--

2

1

= 2

2

2

= 4

2

3

= 8

2

4

= 16

2

5

= 32

2

6

= 64

2

7

= 128

2

8

= 256

Unused

2

0

= 1

2

9

= 512

Zone address 210 (128 + 64 + 16 + 2)

Advertising