CyberDome II

Installation Manual

14

Installing the housing

With the surface prepared and/or the mount now installed, install the housing.

To install a flush-mount housing, see Figure 13 on page 15 and do the following:

1. Remove either conduit knockout (side or top) in the housing.

2. Hold the housing up near the housing passthrough of the mount or cutout.

3. Connect a steel safety cable, if required by local codes.

a. Obtain a steel safety cable of 0.125 in. (3 mm) maximum diameter that complies with local codes.

b. Snip off the nipple that opens access to the safety cable clip.

c. Feed your safety cable through the exposed hole.

d. Secure one end of the safety cable into the safety clip surrounding the exposed hole inside the housing.

e. Secure the other end of the safety cable to the building superstructure.

4. Feed the facility cables through the conduit hole of the housing. Allow enough cable length to make

connections. Figure 9 on page 10 shows how the cables run through the housing.

5. Attach the housing to the mount or ceiling by screwing the housing tabs open and down.

CAUTION: All flush-mount installations must have a fan. If you are installing a flush-mount housing that does not have a

fan, see

Fan installation

on page 16.

CAUTION: For safety, the mounting surface, hardware, and procedure used for securing the dome must support the

weight of the dome, mount (if used), cables, and any structural or environmental vibration according to local codes.
See Table 1 on page 4.