A p p e n d i x l

E - 2

I n s t a l l i n g a P r e c o o l e r

( O p t i o n a l )

(continued)

7

Connect the water discharge or return line with the pressure relief valve to
the precooler outlet.
Use the bracket supplied to secure the pressure relief
valve and discharge line to the back of the dryer.

8

Install the plastic precooler cap over the water connections.

Precooler installed on a D 15, 25,
and 50 dryer without a flow control

Precooler installed on a D 75 and
100 dryer without a flow control

Precooler with a flow control valve
installed on a D 15, 25, and 50 dryer

Precooler with a flow control valve
installed on a D 75 and 100 dryer

Pressure Relief Valve
(Release Pressure 100 psi
[689.5 k Pa])

IMPORTANT: For drying setpoint

temperatures above 150°F

(65.6°C), the precooler must be

bypassed by connecting the dryer

supply hose from the dryer

directly to the hopper inlet.