Conair 100 User Manual

Page 17

Advertising
background image

D e s c r i p t i o n l

2 - 3

2

Description

Central

Central

When supplied for central drying
applications, the D series dryer
is not equipped with a process
heater. Therefore, as a central
dryer, the D dryer will only sup-
ply dry air to the hoppers.

Ty p i c a l A p p l i c a t i o n s

( c o n t i n u e d )

The D carousel dryer can be used successfully in applications that require:

A contamination-free drying environment.

Drying temperatures within the ranges shown in the following table:

Model

Drying Temperature Range

Low temperature (with precooler)*

100° - 150°F (38° - 66°C)

Standard

150° - 250°F (66° - 121°C)

High heat (with aftercooler)

150° - 375°F (66° - 191°C)

Low-high (with aftercooler & precooler)*

100° - 375°F (38° - 191°C)

*Note: See instruction on page 4-12 for setpoints over 150°F (66°C).

Throughput rates of 15 to 100 lbs (6.8 to 37.3 kg) per hour (some materials

can be run at a higher rate).

Dew points of -40°F (-40°C).

If you are drying material at temperatures over 250°F (121°C), you will need the
high-temperature package that includes an aftercooler. An aftercooler is standard
equipment on the High heat and Low-high models.