Conair 100 User Manual

Page 55

Advertising
background image

S c r e e n

Screen 28-43 require access
code 755.

SCREEN 39 (Test Mode Screen)

SCREEN 40 (Test Mode Screen)

SCREEN 41 (Test Mode Screen)

SCREEN 42 (Test Mode Screen)

SCREEN 43 (Test Mode Screen)

F u n c t i o n

C o n t r o l F u n c t i o n D e s c r i p t i o n s

( c o n t i n u e d )

This is the Test Mode screen for the MDC
conveying blower. By pressing the + or -
keys, the setting can be changed. When
set to "On", the conveying blower output
will be turned on for 3 sec. and then shut
off automatically.

Note: If the dryer is not an MDC, nothing

will happen.

This screen is not used in the current pro-
gram.

This screen is not used in the current pro-
gram.

This is the Test Mode screen for the alarm
output (yellow light). By pressing the +
or - keys, the setting can be changed.
When set to "On", the alarm output will be
turned on for 3 sec. and then shut off auto-
matically.

Note: If the optional tricolor light is not

installed, nothing will happen.

This is the Test Mode screen for the alarm
output (green light). By pressing the +
or - keys, the setting can be changed.
When set to "On", the alarm output will be
turned on for 3 sec. and then shut off auto-
matically.

Note: If the optional tricolor light is not

installed, nothing will happen.

off

13

H

off

12

H

off

15

H

off

14

H

off

16

H

O p e r a t i o n l

4 - 1 5

4

Opera

tion

(continued)

Advertising
This manual is related to the following products:

25, 50, 7.5, 15