Conair 100 User Manual

Page 49

Advertising
background image

S c r e e n

Screens 15-27 require access
code 754.

SCREEN 15 (Set up Screen)

SCREEN 16 (Set up Screen)

SCREEN 17 (Set up Screen)

SCREEN 18 (Set up Screen)

SCREEN 19 (Set up Screen)

F u n c t i o n

C o n t r o l F u n c t i o n D e s c r i p t i o n s

( c o n t i n u e d )

This is the process deviation temperature
screen. The range is 5 - 20

°

F (-15.0 -

-6.7

°C)

. This is the deviation temperature

band around the set point. If the dryer
goes outside this band, the dryer will dis-
play a passive alarm (P1).

This is the process high temperature
screen. This is the high temperature limit.
If the process temperature reaches this set-
point, the dryer will shutdown on alarm
A1.

This is the process heater autotune screen.
The autotune function can be turned on by
pressing the + key. Once the + key is
pressed, the screen will show On and then
start the autotune process. This may take a
minute or so to complete. When finished,
the display will read "don". The new PID
values are automatically saved.

This is a regeneration temperature screen.

This is the regeneration heater autotune
screen. The autotune function can be
turned on by pressing the + key. Once the
+ key is pressed, the screen will show On
and then start the autotune process. This
may take a minute or so to complete.
When finished the display will read "don".
The new PID values are automatically
saved.

400

C02

C

off

C03

C

425

C04

C

10

C01

C

off

C05