To S t a r t D r y i n g

(continued)

4

Press the START button.

If everything is installed correctly:

The green light on the start button will illuminate.

The process and regeneration blowers turn on.

The process and regeneration heaters turn on.

If the desiccant tanks are not in their correct position, the carousel will

turn clockwise and stop in the correct position.

To S t o p D r y i n g

1

Press the STOP button. The drying light stays on.

The blowers continue running for a few minutes to cool the heaters.

2

Be sure to disconnect and lockout the
main power
if you have stopped the dryer to
perform maintenance or repair.

IMPORTANT: Do not use the main power switch to
stop the dryer. Turning off power to the control
and dryer during normal operation prevents the
necessary cool-down period, and can trigger the
shut down/high temperature alarm during your
next drying cycle.

Caution: Improper shut down can cause damage to your dryer.

Stop

4 - 1 8

l O p e r a t i o n

Start

Central

The regeneration heater turns on.