Conair 100 User Manual

Page 54

Advertising
background image

S c r e e n

Screen 28-43 require access
code 755.

SCREEN 34 (Test Mode Screen)

SCREEN 35 (Test Mode Screen)

SCREEN 36 (Test Mode Screen)

SCREEN 37 (Test Mode Screen)

SCREEN 38 (Test Mode Screen)

F u n c t i o n

C o n t r o l F u n c t i o n D e s c r i p t i o n s

( c o n t i n u e d )

This is the Test Mode screen for the isola-
tion contactor. By pressing the + or - keys,
the setting can be changed. When set to
"On", the isolation contactor output will be
turned on for 3 sec. and then shut off auto-
matically.

This is the Test Mode screen for the alarm
output (horn and or red light). By pressing
the + or - keys, the setting can be changed.
When set to "On", the alarm output will be
turned on for 3 sec. and then shut off auto-
matically.

Note: The alarm light on the membrane

switch will not come on. If the optional
alarm horn or red light is not installed,
nothing will happen.

This is the Test Mode screen for the pre-
cooler flow control valve. By pressing the
+ or - keys the setting can be changed.
When set to "On" the precooler flow con-
trol valve output will be turned on for 3
sec and then shut off automatically.

Note: If the optional precooler flow control

valve is not installed, nothing will happen.

This is the Test Mode screen for the after-
cooler flow control valve. By pressing the
+ or - keys, the setting can be changed.
When set to "On", the aftercooler flow
control valve output will be turned on for
3 sec. and then shut off automatically.

Note: If the optional aftercooler flow control

valve is not installed, nothing will happen.

This screen is not used in the current pro-
gram.

off

8

H

off

7

H

off

10

H

off

9

H

4 - 1 4

l O p e r a t i o n

off

11

H

Advertising
This manual is related to the following products:

25, 50, 7.5, 15