6 - 1 4

l Tr o u b l e s h o o t i n g

P a s s i v e A l a r m s

Problem

P26

Regen RTD Integrity –

If the process RTD is faulty.

P28

Return Air RTD

Integrity Alarm– If the return
air RTD is faulty.

P30

Out of Hopper RTD

Integrity – The dryer continues
to run with a passive alarm.

Possible cause

The connection in the electrical enclo-
sure for the regen RTD is loose.

The connection of the RTD plug on the
control board is loose.

The regen RTD has failed.

The connection in the electrical enclo-
sure for the return air RTD is loose.

The connection of the RTD plug on the
control board is loose.

The connection of the RTD plug on the
control board is loose.

The return air RTD has failed.

Solution

Check the RTD plug connection and
tighten if needed.

Check the plug connection and tighten if
needed.

Replace the regen RTD.

Check the RTD plug connection and
tighten if needed.

Check the plug connection and tighten if
needed.

Check the plug connection and tighten if
needed.

Replace the return air RTD.