S p e c i f i c a t i o n s : M D C

( c o n t i n u e d )

Central

When config-
ured as a central
dryer, the MDC
option is not
available.

SPECIFICATION NOTES:

* Consult Conair about other available hopper selections.

† SCFM stands for standard cubic feet per minute, referenced to a pre-specified pressure, temperature and relative humidity. In most cases, SCFM is referenced to

14.7 PSIA 68

°

F and 0% relative humidity. ACFM stands for actual cubic feet per minute, and must be supplied with a temperature reference, due to the change in

air density with temperature. Because dryers operate at a relatively low pressure the effects on air density are negligible.

‡ When drying below 150

°

F a precooler is required. When drying above 250

°

F an aftercooler and insulated drying hose is required.

§ Dryers running at 50 HZ will have 17% less airflow, and a 17% reduction in material throughput.

** Temperatures above or below the recommended levels may affect dryer performance. Tower, chiller or municipal water sources can be used.

Throughputs will vary by type of material. Consult Conair for throughput information.

Specifications may change without notice. Check with a Conair representative for the most current information.

Dryer model

MDC15 and MDC25

MDC50

MDC75

MDC100

Hopper selection*

CH10-1

CH10-1.5

CH14-2

CH14-3

CH14-4

CH18-4

CH18-6

CH24-8

CH24-12

CH24-15

Performance characteristics

Air flow {SCFM}†

12

20

35

50

80

Air flow {ACFM @250° }

16

27

47

67

107

Drying temperature‡

All models 100° -375° F {38°-191° C} with options‡

Dew point

All models -40° F {-40° C}

Maximum conveying distance ft {m}

8 {2.44} vertical; 6 {1.83} horizontal

with long-distance option

15 {4.57} vertical; 50 {15.24} horizontal

Dimensions inches {cm}

A - Height to top of hopper

56 {142.2}

67 {170.2}

58 {147.3}

69 {175.3}

80 {203.2}

66 {167.6}

78 {198.1}

76 {193.0}

89 {226.1} 105 {266.7}

B - Total height

100 {254.0} 100 {254.0} 100 {254.0} 100 {254.0} 100 {254.0} 100 {254.0} 100 {254.0} 100 {254.0} 100 {254.0} 105 {266.7}

C - Width

48 {121.9}

48 {121.9}

48 {121.9}

48 {121.9}

48 {121.9}

54 {137.2}

54 {137.2}

54 {137.2}

54 {137.2}

54 {137.2}

D - Depth

30 {76.2}

30 {76.2}

30 {76.2}

30{76.2}

30 {76.2}

36 {91.4}

36 {91.4}

36 {91.4}

36 {91.4}

36 {91.4}

Weight lb {kg}

Shipping

590 {268}

600 {272}

650 {29.5}

660 {299}

670 {304}

785 {356}

805 {365}

1025 {465} 1055 {478} 1075 {488}

Voltages§ Total amps

STD LONG DIST.STDLONG DIST. STANDARD

LONG DIST.

STANDARD

LONG DIST.

STANDARD

LONG DIST.

208V/3 phase/60 Hz

8.6

11

9.5

11.9

12.1

14.5

20.2

22.6

NA

NA

240V/3 phase/60 Hz

7.7

10.1

8.5

10.9

10.8

13.2

17.8

20.2

27.3

29.7

400V/3 phase/50 Hz

4.3

5.4

4.7

5.8

6.2

7.3

10.3

11.4

14.8

15.9

480V/3 phase/60 Hz

3.8

4.6

4.2

5.0

5.4

6.2

8.9

9.7

12.7

13.5

575V/3 phase/60 Hz

3.1

4.5

3.4

4.8

4.4

5.8

7.3

8.7

10.4

11.8

Total kilowatts kW

2.8 3.4 3.1 3.7

4.0

4.6

6.7

7.3

9.6

10.2

Water requirements {for optional aftercooler}

Recommended temperature **

70°-90° F {21°-32° C}

Water flow gpm {liters/min.}

3 {11.36} / 1/2 inch NPT female fittings

A p p e n d i x l

G - 5